Fluid Oscillation Heat Meters

Sontex Superstatic 440

sontex440

Sontex Superstatic 440

The Superstatic 440 is a static heat or cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle, covering a wide range of flows for all applications in district heating and cooling or building automation. The fluid oscillation principle guarantees a high stability and repeatability for a reliable and precise measurement of flow and thermal energy.

The heat meters Superstatic 440 are optimized for the measurement and calculation of energy consumption in district heating systems. They are also extremely well suited to use purely as volumetric flow meters for various media.

  • Interchangeable measuring head
  • Complete range of pipes 1 – 1500 m3/h
  • Purchase and maintenance costs are reasonable compared with other static flow sensors
  • Corrosion resistant materials
  • Threaded and flange fittings
  • No straight section necessary up to DN40
  • No moving parts, therefore no wear
  • Not sensitive to dirt
  • Stable
  • For horizontal, upstream and downstream pipes, independent mounting position
  • Common spare parts 1qp 1 – 1500 m3/h
  • Dynamic range 1 : 100 at 1– 25 m3/h
  • Direct pick-up of voltage pulses without reflectors
  • Measurement independent of medium
  • Long-term, stable, accurate and reliable measurement, even with poor water quality
Top

Sontex Superstatic 449

sontex449

Sontex Superstatic 449

The Superstatic 449 is a battery- or mains powered static compact heat meter. It is used in building automation or in district or local heating to record the consumption-dependent thermal or cooling energy for the billing of thermal energy consumption costs. It covers the range of lower flow rates and energy quantities. The Superstatic 449 meets the requirements of the European guideline MID-2004/22/EC and the standard EN 1434 class 2.

The Superstatic 449 is designed on the basis of the proven fluid oscillation principle used exclusively by Sontex. Due to the use of a static flow sensor, the heat meter Superstatic 449 does not have any moving parts and thus no wear. The fluid oscillation principle guarantees a high stability and repeatability for a reliable and precise measurement of flow and thermal energy.

The Superstatic 449 can be used in the following fields:

  • Thermal heat energy
  • Energy for the production of cooling energy with water

The heat and cooling meters Superstatic 449 are optimized for the measurement and calculation of energy consumption in district or local heating systems. They are also very well suited to use purely as volumetric flow meter for various media.

  • For flows of qp 0.6 – 2.5 m3/h
  • Purchase and maintenance costs are reasonable compared with other static flow sensors
  • Corrosion resistant materials
  • Threaded fittings
  • No moving parts, thus no wear
  • Not sensitive to dirt
  • Stable
  • Dynamic range 1 : 100 at qp 1 – 2.5 m3/h
  • Direct pick-up of voltage pulses without reflectors
  • Medium-independent measurement possible
  • Long-term stability, accurate and reliable measurement
Top

Sontex Superstatic 749

contex-superstaic-749

Sontex Superstatic 749

The Superstatic 749 is an autonomous conpact thermal energy meter consisting of a flow meter an integrator and a pair of temperature sensors.

It’s used in home automation, local and district heating/cooling systems to measure the consumption of heating or cooling energy for the individual heat cost billing. It’s made to measure lower flows and energies.

The compact thermal energy meter Supercal 749 meets the requirements of the European directive 2004/22/EC (MID) and the standard EN 1434 class 2.

Top